Open-source ventilator
ventilator of freely-licensed design

An open source ventilator is a disaster-situation ventilator made using a freely licensed (open-source) design, and ideally, freely available components and parts (open source hardware). Designs, components, and parts may be anywhere from completely reverse-engineered or completely new creations, components may be adaptations of various inexpensive existing products, and special hard-to-find and/or expensive parts may be 3D-printed instead of purchased. As of early 2020, the levels of documentation and testing of open source ventilators was well below scientific and medical-grade standards.
One small, early prototype effort was the Pandemic Ventilator created in 2008 during the resurgence of H5N1 avian influenza that began in 2003, so named "because it is meant to be used as a ventilator of last resort during a possible avian (bird) flu pandemic."
Quality assessment
The policy of using both free and open source software (FOSS) and open source hardware theoretically allows community-wide peer-review and correction of bugs and faults in open source ventilators, which is not available in closed source hardware development. In early 2020 during the COVID-19 pandemic, a review of open source ventilators stated that "the tested and peer-reviewed systems lacked complete documentation and the open systems that were documented were either at the very early stages of design ... and were essentially only basically tested ..." The author speculated that the pandemic would motivate development that would significantly improve the open source ventilators, and that much work, policies, regulations, and funding would be needed for the open source ventilators to achieve medical-grade standards.
Design requirements
A number of features are required for an invasive mechanical ventilator to be safely used on a patient:
a way of measuring and controlling the volume pumped and the breath rate to avoid volutrauma;
monitoring for inspiratory pressure, respiratory rate (bpm), and inspiratory-to-expiratory time (I/E) ratio
for non-sedated patients, an "assist" mode that, instead of forcing air in at a fixed frequency, only increases the pressure when the patient inhales;
for ARDS, support for setting positive end-expiratory pressure (PEEP) to avoid alveoli collapse;
humidification to avoid drying and cooling the alveoli.
The requirements for non-invasive ventilation are less strict.
COVID-19 pandemic
On March 16, 2020, the Open Source Ventilator Ireland (OSV) group was formed initially with the goal of building a focus team in Ireland to begin development on what was termed the "Field Emergency Ventilator (FEV)". Inspired by the initial efforts of the Open Source Medical Supplies (OSCMS), which initially focused on developing open ventilators but quickly refocusing mainly on the local production of Personal Protective Experiment (PPE).
The public source identifies “Open-source ventilator” as ventilator of freely-licensed design. This brief keeps that definition visible, then builds a research path around Open-source, ventilator and freely-licensed.
Why this record matters
A short description can identify a subject without explaining its stakes. For “Open-source ventilator”, the useful work is to connect “ventilator of freely-licensed design” to the records capable of establishing context and consequence.
Vocabulary and entity names are the principal evidence signals here, because they determine the precision of every later search. The source revision retrieved here is dated Aug 24, 2026. The linked authority identifier is Q89433745. The first chronological checks are 2020, 2008 and 2003.
Overview language is designed for orientation and should not be treated as a substitute for the evidence cited beneath it. The source lead contains qualifying language; that uncertainty should survive quotation, summary and reuse. Authority statements aid reconciliation but still require their own references, qualifiers and ranks to be checked.
How to read it
Use the entry as an orientation point, then follow its citations and revision history. Names, dates and institutional relationships should be checked against the original record.
- Subject orientation
- Search vocabulary
- Locating named sources
The closest primary source, responsible institution and strongest cited specialist reference.
Three-step research path
- Establish the record: confirm the title “Open-source ventilator”, its source revision and the description used here.
- Expand the search: follow Open-source ventilator primary sources, Open-source ventilator archive and Open-source research across catalogues and specialist indexes.
- Test the account: compare the strongest cited source with the responsible institution’s current record and note any disagreement.
Questions for further research
- Which source most directly establishes the central claim about “Open-source ventilator”?
- Which institution is responsible for the underlying evidence?
- What terminology or title could unlock a more precise catalogue search?
Search terms from this dossier
This entry incorporates text from “Open-source ventilator” on English Wikipedia. Contributors are listed in the page history. Text is available under the Creative Commons Attribution-ShareAlike 4.0 License. Selected authority identifiers and statements are retrieved from Wikidata under CC0; their references and qualifiers remain part of the verification path.