Mass-analyzed ion-kinetic-energy spectrometry
Open-knowledge reference entry

Mass-analyzed ion kinetic-energy spectrometry (MIKES) is a mass spectrometry technique by which mass spectra are obtained from a sector instrument that incorporates at least one magnetic sector plus one electric sector in reverse geometry (the beam first enters the magnetic sector). The accelerating voltage V, and the magnetic field B, are set to select the precursor ions of a particular m/z. The precursor ions then dissociate or react in an electric field-free region between the two sectors. The ratio of the kinetic energy to charge of the product ions are analyzed by scanning the electric sector field E. The width of the product ion spectrum peaks is related to the kinetic energy release distribution for the dissociation process.
History
MIKES was developed at Purdue University in 1973 by Beynon, Cooks, J. W. Amy, W. E. Baitinger, and T. Y. Ridley. MIKES was invented because researches at Purdue and Cornell thought that if the parent ion was mass-selected before the dissociation and mass analysis of the products by the electric sector it would be easier to study the metastable ions and the collision-induced dissociation (CID). This was an achievement because it combined the utility of previous instruments such as the ion kinetic energy spectrometer with the ability to mass select precursor ions. That precursor ion is mass selected with the magnetic sector. The dissociation products are then mass analyzed using the electric sector. "The peak shapes revealed from the electric sector scan can provide information on the kinetic energy release from in the course of fragmentation and on the kinetic energy uptake in the course of ionic collision processes." The dispersion of velocities due to kinetic energy release leads to the characteristic wide metastable peaks observed using MIKES techniques.
This brief starts where responsible research should: with the source description of “Mass-analyzed ion-kinetic-energy spectrometry” as open-knowledge reference entry. Everything that follows is an evidence route, not borrowed authority.
Why this record matters
The subject matters to the general reference register because the source frames it as open-knowledge reference entry. Its deeper value depends on whether names, dates, institutions and citations support that framing.
The citation trail is more important than the brevity of the summary: it shows where individual claims can be examined in context. The source revision retrieved here is dated May 26, 2025. The linked authority identifier is Q3966578. None of the 0 selected statements returned an explicit reference. The first chronological checks are 1973.
A concise general-reference account can conceal disagreements about scope, terminology or the weight assigned to individual sources. The lead is largely declarative, so disagreement and counter-evidence require a deliberate search beyond the opening account. Authority statements aid reconciliation but still require their own references, qualifiers and ranks to be checked.
How to read it
Use the entry as an orientation point, then follow its citations and revision history. Names, dates and institutional relationships should be checked against the original record.
- Subject orientation
- Search vocabulary
- Locating named sources
The closest primary source, responsible institution and strongest cited specialist reference.
Three-step research path
- Establish the record: confirm the title “Mass-analyzed ion-kinetic-energy spectrometry”, its source revision and the description used here.
- Expand the search: follow Mass-analyzed ion-kinetic-energy spectrometry primary sources, Mass-analyzed ion-kinetic-energy spectrometry archive and Mass-analyzed research across catalogues and specialist indexes.
- Test the account: compare the strongest cited source with the responsible institution’s current record and note any disagreement.
Questions for further research
- Which source most directly establishes the central claim about “Mass-analyzed ion-kinetic-energy spectrometry”?
- What terminology or title could unlock a more precise catalogue search?
- Which cited source is closest to the event, object or claim?
Search terms from this dossier
This entry incorporates text from “Mass-analyzed ion-kinetic-energy spectrometry” on English Wikipedia. Contributors are listed in the page history. Text is available under the Creative Commons Attribution-ShareAlike 4.0 License. Selected authority identifiers and statements are retrieved from Wikidata under CC0; their references and qualifiers remain part of the verification path.