CACrown ArchivesThe cinema collection
Menu
Research dossier · Science & Nature

MEMS

technology of very small devices

Specimen drawers, botanical folios and brass scientific instruments under study light
Science and natureInterpretive dossier study · Crown Archives visual atlas
Record originEnglish Wikipedia
Text licenseCC BY-SA 4.0
Source revisionSep 20, 2026
Entity authorityQ175561
Source-derived summary

MEMS (micro-electromechanical systems) is the technology of microscopic devices incorporating both electronic and moving parts. MEMS are made up of components between 1 and 100 micrometres in size (i.e., 0.001 to 0.1 mm), and MEMS devices generally range in size from 20 micrometres to a millimetre (i.e., 0.02 to 1.0 mm), although components arranged in arrays (e.g., digital micromirror devices) can be more than 1000 mm2. They usually consist of a central unit that processes data (an integrated circuit chip such as microprocessor) and several components that interact with the surroundings (such as microsensors).

Because of the large surface area to volume ratio of MEMS, forces produced by ambient electromagnetism (e.g., electrostatic charges and magnetic moments), and fluid dynamics (e.g., surface tension and viscosity) are more important design considerations than with larger scale mechanical devices. MEMS technology is distinguished from molecular nanotechnology or molecular electronics in that the latter two must also consider surface chemistry.

The potential of very small machines was appreciated before the technology existed that could make them (see, for example, Richard Feynman's famous 1959 lecture "There's Plenty of Room at the Bottom"). MEMS became practical once they could be fabricated using modified semiconductor device fabrication technologies, normally used to make electronics. These include molding and plating, wet etching (KOH, TMAH) and dry etching (RIE and DRIE), electrical discharge machining (EDM), and other technologies capable of manufacturing small devices.

They merge at the nanoscale into nanoelectromechanical systems (NEMS) and nanotechnology.

History

An early example of a MEMS device is the resonant-gate transistor, an adaptation of the MOSFET, developed by Robert A. Wickstrom for Harvey C. Nathanson in 1965.

Editorial summary

This brief starts where responsible research should: with the source description of “MEMS” as technology of very small devices. Everything that follows is an evidence route, not borrowed authority.

Editorial reviewUseful for establishing the present vocabulary of the subject while preserving a route back to the evidence on which that vocabulary rests. The current lead gives the account dated anchors—1000, 1959, 1965—that can be checked directly. The selected authority fields contribute no independent date. The account is most persuasive where MEMS, technology and very can be independently traced.
Editorial analysis

Why this record matters

The subject matters to the science & nature register because the source frames it as technology of very small devices. Its deeper value depends on whether names, dates, institutions and citations support that framing.

Evidence profile

The date and method of observation matter as much as the stated conclusion, especially where classification or consensus has changed. The source revision retrieved here is dated Sep 20, 2026. The linked authority identifier is Q175561. The Library of Congress control number is sh97007351. 1 of 1 selected statements include explicit references; 1 carry qualifiers and 0 use preferred rank. The first chronological checks are 1000, 1959 and 1965.

Critical limits

Scientific names, classifications and consensus can change while older terminology persists in catalogues and historical literature. The source lead contains qualifying language; that uncertainty should survive quotation, summary and reuse. Authority statements aid reconciliation but still require their own references, qualifiers and ranks to be checked.

How to read it

Check terminology, classification and the date of the cited evidence. Scientific names and technical consensus can change while older records retain historical value.

Best used for
  • Current terminology
  • Classification context
  • Finding cited technical literature
Verify next

Primary datasets, specimen catalogues, standards bodies and the most recent peer-reviewed literature.

Three-step research path

  1. Establish the record: confirm the title “MEMS”, its source revision and the description used here.
  2. Expand the search: follow MEMS primary sources, MEMS archive and MEMS research across catalogues and specialist indexes.
  3. Test the account: compare the strongest cited source with the responsible institution’s current record and note any disagreement.

Questions for further research

  1. Which source most directly establishes the central claim about “MEMS”?
  2. Is the terminology current, historical or disputed?
  3. Which observation, specimen, dataset or publication supports the account?
Subject index

Search terms from this dossier

Source & attribution

This entry incorporates text from MEMS” on English Wikipedia. Contributors are listed in the page history. Text is available under the Creative Commons Attribution-ShareAlike 4.0 License. Selected authority identifiers and statements are retrieved from Wikidata under CC0; their references and qualifiers remain part of the verification path.