CACrown ArchivesThe cinema collection
Menu
Research dossier · General Reference

Orifice plate

restriction used to measure flow or to control pressure or flow, sometimes given specialised names

Cross-disciplinary reference desk with index cards, atlas, dictionary and catalogue
General referenceInterpretive dossier study · Crown Archives visual atlas
Record originEnglish Wikipedia
Text licenseCC BY-SA 4.0
Source revisionJun 22, 2026
Entity authorityQ1240867
Source-derived summary

An orifice plate is a device used for measuring flow rate, reducing pressure or restricting flow (in the latter two cases it is often called a restriction plate).

Description

An orifice plate is a thin plate with a hole in it, which is usually placed in a pipe. When a fluid (whether liquid or gaseous) passes through the orifice, its pressure builds up slightly upstream of the orifice but as the fluid is forced to converge to pass through the hole, the velocity increases and the fluid pressure decreases. A little downstream of the orifice the flow reaches its point of maximum convergence, the vena contracta (see drawing to the right) where the velocity reaches its maximum and the pressure reaches its minimum. Beyond that, the flow expands, the velocity falls and the pressure increases. By measuring the difference in fluid pressure across tappings upstream and downstream of the plate, the flow rate can be obtained from Bernoulli's equation using coefficients established from extensive research.

In general, the mass flow rate

q

m

{\displaystyle q_{m}}

measured in kg/s across an orifice can be described as

q

m

=

C

d

1

β

4

ϵ

π

4

d

2

2

ρ

1

Δ

p

,

{\displaystyle q_{m}={\frac {C_{d}}{\sqrt {1-\beta ^{4}}}}\epsilon {\frac {\pi }{4}}d^{2}{\sqrt {2\rho _{1}\Delta p}},}

where

The volume flow rate

q

v

{\displaystyle q_{v}}

measured in m3/s is

q

v

=

q

m

ρ

1

.

{\displaystyle q_{v}={\frac {q_{m}}{\rho _{1}}}.}

The overall pressure loss in the pipe due to an orifice plate is lower than the measured differential pressure, typically by a factor of

1

β

1.9

{\displaystyle 1-\beta ^{1.9}}

.

Application

Orifice plates are most commonly used to measure flow rates in pipes, when the fluid is single-phase (rather than being a mixture of gases and liquids, or of liquids and solids) and well-mixed, the flow is continuous rather than pulsating, the fluid occupies the entire pipe (precluding silt or trapped gas), the flow profile is even and well-developed and the fluid and flow rate meet certain other conditions. Under these circumstances and when the orifice plate is constructed and installed according to appropriate standards, the flow rate can easily be determined using published formulae based on substantial research and published in industry, national and international standards.

Editorial summary

This brief starts where responsible research should: with the source description of “Orifice plate” as restriction used to measure flow or to control pressure or flow, sometimes given specialised names. Everything that follows is an evidence route, not borrowed authority.

Editorial reviewA practical starting point whose main value is the path it opens into stronger specialist and primary sources. The current 380-word lead offers orientation but no explicit four-digit date, so chronology should not be assumed. The selected authority fields contribute no independent date. The account is most persuasive where Orifice, plate and restriction can be independently traced.
Editorial analysis

Why this record matters

The subject matters to the general reference register because the source frames it as restriction used to measure flow or to control pressure or flow, sometimes given specialised names. Its deeper value depends on whether names, dates, institutions and citations support that framing.

Evidence profile

Vocabulary and entity names are the principal evidence signals here, because they determine the precision of every later search. The source revision retrieved here is dated Jun 22, 2026. The linked authority identifier is Q1240867. None of the 0 selected statements returned an explicit reference.

Critical limits

The absence of detail may reflect summary conventions rather than a lack of surviving documentation. The lead is largely declarative, so disagreement and counter-evidence require a deliberate search beyond the opening account. Authority statements aid reconciliation but still require their own references, qualifiers and ranks to be checked.

How to read it

Use the entry as an orientation point, then follow its citations and revision history. Names, dates and institutional relationships should be checked against the original record.

Best used for
  • Subject orientation
  • Search vocabulary
  • Locating named sources
Verify next

The closest primary source, responsible institution and strongest cited specialist reference.

Three-step research path

  1. Establish the record: confirm the title “Orifice plate”, its source revision and the description used here.
  2. Expand the search: follow Orifice plate primary sources, Orifice plate archive and Orifice research across catalogues and specialist indexes.
  3. Test the account: compare the strongest cited source with the responsible institution’s current record and note any disagreement.

Questions for further research

  1. Which source most directly establishes the central claim about “Orifice plate”?
  2. Which cited source is closest to the event, object or claim?
  3. What terminology or title could unlock a more precise catalogue search?
Subject index

Search terms from this dossier

Source & attribution

This entry incorporates text from Orifice plate” on English Wikipedia. Contributors are listed in the page history. Text is available under the Creative Commons Attribution-ShareAlike 4.0 License. Selected authority identifiers and statements are retrieved from Wikidata under CC0; their references and qualifiers remain part of the verification path.